NLRequest an API key
Guides

Interpolating meter data

A meter reading is missing, but the readings before and after it are known. Then you can interpolate the gap. This is how it works for meter readings.

Readings, not consumption per interval

A meter reading is the register value at a point in time, in kWh. The difference with the previous reading is the consumption. So interpolate the readings and compute consumption afterwards. That way the total over the gap is always right: it is the difference between the two known readings.

An example

Two readings are missing, the rest is known.

timereading (kWh)
08:0012347.494measured
08:1512347.649repaired
08:3012347.803repaired
08:4512347.957measured

The difference is 0.463 kWh over three intervals, about 0.154 kWh each. The repaired readings are rounded to whole Wh, the way a register counts. The total stays 0.463 kWh.

When linear is not enough

The Dutch market has its own method for smart meters, described in IC274. It spreads consumption over a gap using profile fractions. eclipse currently works linearly.